Sizing an MBR: the data we need from you

The handful of numbers that decide which MBR cassette you need, and why peak flow matters more than average flow.

25 November 2026 · 5 min read

Start with flow

Membrane area follows from how much water you must filter and the flux the membrane can sustain. As a rule, area equals the hourly flow divided by the design flux. Flux is the litres of water that pass through each square metre of membrane per hour (L/m²h). The datasheets give an operating range, and the right point in that range depends on your water.

The arithmetic, once

A worked example, for illustration. A plant treats 500 KLD, which is 500,000 litres a day, or about 20,800 litres an hour averaged over 24 hours. At a design flux of 20 L/m²h the membrane area is about 1,040 m².

Now suppose the flow peaks at 1.5 times the average for a few hours. At the peak the plant must pass about 31,250 litres an hour. If the flux must not go above 20 L/m²h, the area has to be about 1,560 m². That is half as much again, which is why we ask for the peak.

Average flow is not enough

Plants rarely see a steady flow. Batch processes and daily peaks can push flow well above the average for several hours. A membrane sized for the average will run at too high a flux at the peak, and fouling follows. Tell us the average, the peak and how long the peak lasts, or add an equalisation tank to flatten it.

AveragePeak: sets the areaWith an equalisation tank Hours of the dayFlow
An illustrative daily flow. The peak, not the average, sets the membrane area unless an equalisation tank flattens it.

What we ask for

Send as many of these as you can:

  • Daily flow in KLD, and the peak flow
  • Feed water analysis: COD, BOD, suspended solids, TDS
  • pH range and temperature range
  • Oil, grease, surfactants or other unusual compounds
  • MLSS you plan to run, or your existing biological design
  • Tank dimensions, if you are retrofitting

Design flux by product

The datasheets give operating ranges, and the lower end suits harder water. These are the ranges we start from.

  • REINFLO: 10–20 L/m²h on effluent and 20–30 L/m²h on sewage
  • HI-FLO: 15–30 L/m²h typical filtrate flux
  • AEROFLO: sized by module area, from 5 to 15 m² per module
  • Higher oil, surfactants or sludge solids push the design flux to the lower end
SRP REINFLO cassette in a stainless steel frame
An SRP REINFLO cassette. Cassette area is chosen to match the design flux.

Why the details matter

pH and temperature decide which membrane is suitable. AEROFLO, for example, is rated for an operating pH of 6–9, REINFLO for 1–12 and HI-FLO for 2–12. High fouling or high oil content pushes the design flux down, which means more membrane area.

Starting from the datasheet ranges

Each SRP cassette has a rated range of suitable flow in KLD. The membrane finder uses those ranges to give you a first selection. Our engineers then confirm it against your data before we quote.

FAQ

Quick answers.

Can I size an MBR from daily flow alone?

You can get a starting point, which is what the membrane finder gives. A confirmed design also needs peak flow, feed quality, pH and temperature.

What happens if the membrane is undersized?

It runs at a higher flux than planned, fouls faster and needs more frequent cleaning. Sizing for the peak avoids this.

Talk to our engineers

Tell us about your water.

Share your application and daily flow. We reply with a suitable membrane or a complete treatment system.

  • +91 90565 26208Call or WhatsApp
  • crm@srpepl.comQuotes and datasheets
  • 70, Industrial Area, Phase - I, Panchkula, Haryana, India - 134113Head office
  • Jebel Ali Free Zone, Dubai, U.A.E.International office