Who is SRP Membranes?

SRP Membranes is the membrane manufacturing division of SR Paryavaran. We make MBR, UF and RO membranes and supply complete treatment systems built around them.

Do you supply only membranes, or the whole plant?

Both. SRP Membranes makes the membranes, and SR Paryavaran designs and builds the treatment system. You can buy modules for an existing plant or a complete system from one supplier.

What is the difference between MBR, UF and RO?

An MBR combines biological treatment with membrane filtration and removes solids and bacteria. UF is a finer filtration step that removes suspended particles and bacteria without biology. RO removes dissolved salts.

How do I get a quote?

Use the contact page or the form on any product page. Give your application, daily flow and feed water details, and our engineers will reply.

Are datasheets free to download?

Yes. Datasheets are free on the downloads page. If one is not listed yet, request it and we will send it.

Where are you based?

Our head office is in Panchkula, Haryana, India. Our international office is in the Jebel Ali Free Zone, Dubai, U.A.E.

SRP AEROFLO View page

What is the SRP AEROFLO membrane?

SRP AEROFLO is a submerged MBR membrane made of corrugated PVDF flat sheet on a PET support board. It has a nominal pore size of 0.1 µm and is supplied as modules with a surface area of 5 to 15 m².

What pH and temperature can AEROFLO operate at?

The datasheet gives an operating pH of 6–9 and a temperature range of 5–35 °C. For cleaning, the pH range is 2–11. Cleaning uses NaOCl or citric acid.

How much energy does the corrugated design save?

The datasheet states a saving of 10–15% compared with traditional flat membranes, because the structure reduces resistance and improves filtration dynamics.

What MLSS range does AEROFLO handle?

The datasheet gives an MLSS range of 6,000 to 15,000 mg/L.

Can the pore size be changed?

The nominal pore size is 0.1 µm, and the datasheet notes that the filtration degree can be changed on client request. Contact us with your requirement.

Does AEROFLO need changes to my existing plant?

The datasheet states that the membrane integrates with existing systems without modification. Send us your tank and process details and we will confirm the fit.

SRP HI-FLO View page

What is the SRP HI-FLO membrane?

SRP HI-FLO is a submerged MBR flat sheet membrane made of PTFE with a nominal pore size of 0.02 µm. It is supplied as cassettes with a total area from 10 to 480 m².

Can HI-FLO run without a suction pump?

Yes. The membrane has a porosity above 85% and low filtration resistance, so at common flux the TMP is below 0.5 m of water head. That makes gravity filtration possible. Suction filtration is also supported.

What pH range and cleaning chemicals does HI-FLO tolerate?

The datasheet gives a pH range of 2–12 and a CIP chlorine concentration of 5,000 ppm. Cleaning uses NaOCl or citric acid, and the PTFE membrane tolerates strong acid, alkali and oxidant cleaning.

How does HI-FLO lower operating cost?

Cassettes stack in layers, which cuts the footprint and the aeration flow. The datasheet states a saving of at least 70% of the operating cost of a conventional flat MBR.

Which wastewater is HI-FLO used for?

The datasheet lists petrochemical, oilfield (ASP flooding), saline organic and municipal wastewater.

How do I choose a HI-FLO cassette?

Use the membrane selector for a first estimate from your daily flow in KLD, or send us your flow and effluent quality and our engineers will size it.

SRP REINFLO View page

What is the SRP REINFLO membrane?

SRP REINFLO is a submerged MBR capillary membrane made of reinforced PVDF with a nominal pore size of 0.03 µm. The membranes are built into RF08, RF16 and RF35 modules, which are assembled into cassettes with a total area from 40 to 1,750 m².

What pH range and cleaning chemicals can REINFLO tolerate?

The datasheet gives an operating pH range of 1–12. The membrane tolerates sodium hypochlorite (NaOCl) up to 5,000 mg/L, so it can be cleaned with a strong oxidising agent.

What operating flux and pressure does REINFLO use?

The datasheet lists an operating flux of 10–20 L/m²h for effluent treatment plants (ETP) and 20–30 L/m²h for sewage treatment plants (STP). Maximum transmembrane pressure is 10–50 kPa and operating temperature is 5–40 °C.

Which REINFLO cassette suits my flow?

Rated flow runs from 15–25 KLD for the 40C cassette up to 670–1,100 KLD for the 1750M. Use the membrane selector for a first match. Final sizing depends on your feed water, temperature and design flux, so send us your data to confirm.

What does reinforced PVDF mean for fouling-heavy wastewater?

Each capillary is reinforced with a net tube and the membrane is bonded to it, which adds strength and removes the problem of the membrane peeling. The datasheet also notes a more uniform pore size and less pore swelling.

Can I buy only membranes, or a complete treatment system?

Both. SRP Membranes manufactures the membranes, and SR Paryavaran designs and builds the treatment system around them.

SRP RO Elements View page

What is the difference between BW, ULP and SW elements?

BW elements treat brackish water at low pressure. ULP elements work at ultra-low pressure and suit energy-efficient duties. SW elements are for seawater desalination and have the highest rejection, at 99.85%.

What does FR mean in SRP BW 8040 FR?

The FR element has a surface treatment that improves hydrophilicity, electric charge and roughness. That reduces the build-up and adsorption of pollutants and microbes on the membrane surface.

What are the operating limits of SRP RO elements?

The maximum operating temperature is 45 °C and the maximum pressure is 41 bar (600 psig). Continuous operation is rated for pH 2–11, and short-term cleaning for pH 1–13. The maximum feed SDI is 5.

Can SRP RO elements tolerate chlorine?

No. Free chlorine must stay below 0.1 ppm. The datasheet recommends removing residual free chlorine by pre-treatment, because oxidation damage can cause early failure.

How much permeate does an 8040 element give?

Under the test conditions in the datasheet, BW, BW FR and ULP 8040 elements give 10,000 gpd (37.9 m³/d), and the SW 8040 gives 7,500 gpd (28.4 m³/d). Permeate flow of individual elements may vary by ±15%.

Do you also design the RO system?

Yes. SRP Membranes makes the elements and SR Paryavaran designs and builds the plant. Send us your feed water data and we will size it.

SRP 8040 Series View page

What is the difference between BW, ULP and SW elements?

BW elements treat brackish water at low pressure. ULP elements work at ultra-low pressure and suit energy-efficient duties. SW elements are for seawater desalination and have the highest rejection, at 99.85%.

What does FR mean in SRP BW 8040 FR?

The FR element has a surface treatment that improves hydrophilicity, electric charge and roughness. That reduces the build-up and adsorption of pollutants and microbes on the membrane surface.

What are the operating limits of SRP RO elements?

The maximum operating temperature is 45 °C and the maximum pressure is 41 bar (600 psig). Continuous operation is rated for pH 2–11, and short-term cleaning for pH 1–13. The maximum feed SDI is 5.

Can SRP RO elements tolerate chlorine?

No. Free chlorine must stay below 0.1 ppm. The datasheet recommends removing residual free chlorine by pre-treatment, because oxidation damage can cause early failure.

How much permeate does an 8040 element give?

Under the test conditions in the datasheet, BW, BW FR and ULP 8040 elements give 10,000 gpd (37.9 m³/d), and the SW 8040 gives 7,500 gpd (28.4 m³/d). Permeate flow of individual elements may vary by ±15%.

Do you also design the RO system?

Yes. SRP Membranes makes the elements and SR Paryavaran designs and builds the plant. Send us your feed water data and we will size it.

SRP 4040 Series View page

What is the difference between BW 4040 and ULP 4040?

BW 4040 treats brackish water at low pressure. ULP 4040 works at ultra-low pressure and suits energy-efficient duties. Both give 2,350 gpd (8.9 m³/d) at 99.2% stabilised rejection under the datasheet test conditions.

What are the operating limits of SRP RO elements?

The maximum operating temperature is 45 °C and the maximum pressure is 41 bar (600 psig). Continuous operation is rated for pH 2–11, and short-term cleaning for pH 1–13. The maximum feed SDI is 5.

Can SRP RO elements tolerate chlorine?

No. Free chlorine must stay below 0.1 ppm. The datasheet recommends removing residual free chlorine by pre-treatment, because oxidation damage can cause early failure.

Do you also design the RO system?

Yes. SRP Membranes makes the elements and SR Paryavaran designs and builds the plant. Send us your feed water data and we will size it.

How much permeate does a 4040 element give?

Under the datasheet test conditions, BW 4040 and ULP 4040 elements give 2,350 gpd (8.9 m³/d). Permeate flow of individual elements may vary by ±15%.

SRP ULTRAFLO 3000 View page

What is the SRP ULTRAFLO 3000 series?

It is a pressurised, outside-in ultrafiltration module made of PVDF capillary membranes with a nominal pore size of 0.03 µm. Modules are available with 40, 80 and 110 m² of filtration area.

What are the operating limits of ULTRAFLO 3000?

The datasheet gives a maximum feed pressure of 0.5 MPa (73 psi), a maximum TMP and backwash pressure of 0.2 MPa (30 psi), an operating temperature of 5–40 °C and an operating pH of 2–10.

How are ULTRAFLO modules cleaned?

Backwash runs every 15–60 minutes for 30–120 seconds with air scouring, and a chemically enhanced backwash (CEB) runs at least once a day. Cleaning chemicals include NaOCl or H₂O₂, NaOH, HCl, citric acid and oxalic acid.

What is the difference between the standard and Teelink end caps?

The standard cap uses 2" Victaulic connections for feed, permeate and concentrate. The Teelink specialised cap uses 2½" Victaulic for feed and permeate and 2" for concentrate.

Can ULTRAFLO be used ahead of reverse osmosis?

Yes. The datasheet lists treatment of surface water or seawater for RO and NF systems as an application.

SRP ULTRAFLO 4000 View page

What is the SRP ULTRAFLO 4000 series?

It is a pressurised ultrafiltration module made of reinforced PVDF capillary membranes with a nominal pore size of 0.03 µm. Modules are available with 25, 50 and 75 m² of filtration area.

How does ULTRAFLO 4000 differ from ULTRAFLO 3000?

ULTRAFLO 4000 uses reinforced PVDF capillaries (1.0 mm ID, 2.6 mm OD) with a typical flux of 70–120 L/m²h. ULTRAFLO 3000 uses PVDF capillaries (0.7 mm ID, 1.3 mm OD) with a typical flux of 40–100 L/m²h.

What are the operating limits of ULTRAFLO 4000?

The datasheet gives a maximum feed pressure of 0.5 MPa (73 psi), a maximum TMP and backwash pressure of 0.2 MPa (30 psi), an operating temperature of 5–40 °C and an operating pH of 2–10.

How are ULTRAFLO 4000 modules cleaned?

Backwash runs every 15–60 minutes for 30–120 seconds, and a chemically enhanced backwash runs at least once a day. The CIP chlorine concentration is 1,000–3,000 ppm.

Where is ULTRAFLO 4000 used?

It suits wastewater applications where both mechanical robustness and high separation performance are needed.

Brackish and seawater desalination View page

Which element suits seawater?

The SRP SW 8040, with 99.85% stabilised salt rejection.

Which element suits brackish water?

BW and BW FR elements for brackish water, or ULP where you want to run at ultra-low pressure.

Do I need pre-treatment?

RO needs clean feed. UF pre-treatment is the usual way to protect the elements.

What is the maximum RO operating pressure?

The datasheet gives 41 bar (600 psig) and a maximum operating temperature of 45 °C.

Food and beverage View page

Can treated water be reused in food production?

Treated water can be reused where it meets the quality your process and local rules require. Final quality depends on the whole treatment train.

Which SRP membrane suits food and beverage plants?

The AEROFLO datasheet lists food and beverage processing. REINFLO suits plants with variable loads and pH swings.

Do you also supply the plant?

Yes. SR Paryavaran designs and builds the plant around SRP membranes.

How do I size the system?

Send us your flow and effluent quality, or try the membrane finder for a first estimate.

Industrial and textile effluent View page

Can an MBR treat textile effluent?

Yes. A membrane bioreactor combines biological treatment with membrane filtration, so it removes suspended solids and bacteria and produces a consistent permeate. Textile permeate usually still carries dissolved solids (TDS) and residual colour, so a reverse osmosis stage is normally added when the water is to be reused in the process.

Which SRP MBR membrane suits wastewater with a wide pH swing?

SRP REINFLO is rated for an operating pH of 1–12, the widest of the three MBR lines. AEROFLO is rated for pH 6–9 and HI-FLO for pH 2–12. Final selection depends on your feed water, so send us your effluent data and we will confirm.

Can treated textile effluent be reused?

In many plants, yes. Membrane-treated water, followed by reverse osmosis where dissolved salts need to come down, can go back to utilities or suitable process steps. The quality your process needs sets how far the water must be treated.

What happens to the reverse osmosis reject?

The reject is a concentrated, high-salinity stream. It can be reduced further with disc-tube RO (DTRO) and then handled through a zero-liquid discharge scheme, which recovers more water and minimises the liquid left to dispose of.

Does SRP supply only membranes, or the whole treatment plant?

Both. SRP Membranes manufactures the membranes, and SR Paryavaran designs and builds the treatment system around them. You can buy modules for an existing plant or a complete effluent treatment plant from one supplier.

How do I size a membrane system for my flow?

Use the membrane selector on this site for a first estimate from your daily flow in KLD, or send us your flow and effluent quality and our engineers will size it. Final sizing depends on feed water, temperature and design flux.

Municipal sewage treatment View page

Can an MBR be used for municipal sewage?

Yes. The datasheets list municipal wastewater treatment as an application for REINFLO, AEROFLO and HI-FLO.

Can we upgrade an existing plant with membranes?

Often. AEROFLO is designed to integrate with existing systems without modification, and it suits upgrades. Send us your tank details and we will check the fit.

Which MBR suits a large plant?

SRP REINFLO cassettes go up to 1,750 m² each with a rated flow up to 1,100 KLD per cassette, which suits large plants.

Can the treated water be reused?

Yes. A UF or RO stage after the MBR brings the water to a quality suitable for reuse, depending on your requirement.

Oil, gas and petrochemical View page

Can an MBR treat petrochemical wastewater?

The HI-FLO datasheet lists petrochemical wastewater treatment to meet discharge requirements, and ASP flooding oilfield wastewater, as applications.

Which SRP membrane tolerates the widest pH range?

REINFLO, rated for operating pH 1–12. HI-FLO covers pH 2–12.

Can the membranes be cleaned with strong chemicals?

REINFLO tolerates NaOCl up to 5,000 mg/L and HI-FLO a CIP chlorine concentration of 5,000 ppm.

What about the RO reject?

DTRO and zero-liquid discharge can reduce it. Send us your stream data and we will advise.

Water reclamation and reuse View page

What can reclaimed water be used for?

Common uses include agriculture, industrial processes and non-potable supply. The quality needed for your use sets how far the water must be treated.

Do I need RO for reuse?

Only if dissolved salts must come down. For many non-potable uses, MBR or UF alone is enough.

Can SRP supply the whole reclamation plant?

Yes. SRP Membranes supplies the membranes and SR Paryavaran designs and builds the plant.

What about the RO reject?

It is a concentrated stream. DTRO and zero-liquid discharge can reduce it further.

Talk to our engineers

Tell us about your water.

Share your application and daily flow. We reply with a suitable membrane or a complete treatment system.

  • +91 90565 26208Call or WhatsApp
  • crm@srpepl.comQuotes and datasheets
  • 70, Industrial Area, Phase - I, Panchkula, Haryana, India - 134113Head office
  • Jebel Ali Free Zone, Dubai, U.A.E.International office