Membrane manufacturing division of SR Paryavaran +91 90565 26208crm@srpepl.com

Spiral-wound polyamide RO elements, 8040 size

SRP 8040 RO elements

Brackish water, fouling-resistant, ultra-low-pressure and seawater reverse osmosis elements in the 8-inch size, 400 ft² (37.2 m²) of active area.

ModelsBW, BW FR, ULP, SW Active area37.2 m² RejectionUp to 99.85% Max pressure41 bar
SRP 8040 RO membrane element

Overview

Four 8040 elements for every feed.

SRP 8040 elements are spiral-wound polyamide thin-film composite membranes. The range covers brackish water (BW and BW FR), ultra-low pressure (ULP) and seawater (SW) duties.

8040 elements fit a nominal 8-inch pressure vessel, are 40 inches (1016 mm) long and have 37.2 m² of active area. SRP makes the elements, so you can also have them sized into a complete treatment system.

Why SRP 8040 Series

Four 8040 elements, one size.

01

BW 8040

Brackish water element with low operating pressure, high permeate flow and high rejection of soluble salt, TOC and SiO₂. 99.6% stabilised rejection.

02

BW FR 8040

A surface treatment improves hydrophilicity, charge and roughness, which reduces the build-up of pollutants and microbes on the membrane. 99.6% stabilised rejection.

03

ULP 8040

Works at ultra-low pressure, with a flux and rejection that rival common low-pressure elements. 99.5% stabilised rejection.

04

SW 8040

For seawater desalination, with high rejection, stable performance, low operating cost and small equipment investment. 99.85% stabilised rejection.

Dimensions

8040 element dimensions.

The 8040 spiral-wound element. All four 8040 models share one size.

1016Ø202core tubeSRP 8040 (BW, BW FR, ULP, SW)
All dimensions in millimetres, front view and end view. Elements are drawn to the same scale.
Model Length A (mm) Outer Ø (mm) Core tube Ø (mm)
SRP 8040 (BW, BW FR, ULP, SW) 1016 202 29

From the datasheet drawings. 8040 elements fit a nominal 8-inch pressure vessel.

Specifications

Technical data.

Figures are taken from the SRP 8040 datasheet. Specifications may change as improvements are made.

Element construction
Element typeSpiral-wound, polyamide thin-film composite
Length40.0 in (1016 mm)
Diameter8 in (202 mm)
Permeate tube1.125 in (29 mm)
VesselNominal 8-inch ID pressure vessel
Operating conditions
Maximum operating temperature45 °C (113 °F)
Maximum temperature above pH 1035 °C (95 °F)
Maximum operating pressure41 bar (600 psig)
Maximum element pressure drop1.0 bar (15 psig)
pH, continuous operation2–11
pH, short-term cleaning (30 min)1–13
Maximum feed SDI5
Free chlorine tolerance< 0.1 ppm
8040 elements
Element Area (ft²) Area (m²) Thickness (mil) Flow (gpd) Flow (m³/d) Salt rejection (%)
SRP BW 8040 400 37.2 34 10,000 37.9 99.6
SRP BW 8040 FR 400 37.2 34 10,000 37.9 99.6
SRP ULP 8040 400 37.2 34 10,000 37.9 99.5
SRP SW 8040 400 37.2 34 7,500 28.4 99.85

Test conditions: BW, BW FR and SW at 2,000 ppm NaCl and 225 psi (1.55 MPa); ULP at 1,500 ppm NaCl and 150 psi (1.03 MPa). All at 25 °C (77 °F), pH 7.5 and 15% recovery. Rejection is the stabilised figure. Flow of individual elements may vary by ±15%, and minimum salt rejection is 99.0%. Active area is guaranteed ±5%.

SRP 8040 Series datasheet

PDF, 8 pages, 9.2 MB. BW 8040, BW 8040 FR, ULP 8040 and SW 8040: specifications, dimensions and operating limits, one page per model.

Download PDF

Applications

Where SRP 8040 Series is used.

  • Brackish water desalination. BW and BW FR elements bring down dissolved salts, TOC and SiO₂.
  • Seawater desalination. SW elements produce qualified drinking water from seawater.
  • High-purity water. Pure water production for the electricity and electronics industries.
  • Process water treatment. BW and ULP 8040 elements serve industrial process water and boiler make-up.
  • Energy-efficient treatment. ULP elements deliver high flow at ultra-low operating pressure.

Advantages

What you gain.

  • Low operating pressure with high permeate flow.
  • High rejection of salts, TOC and silica.
  • Supplied by the same company that builds the treatment system.

FAQ

SRP 8040 Series questions, answered.

What is the difference between BW, ULP and SW elements?

BW elements treat brackish water at low pressure. ULP elements work at ultra-low pressure and suit energy-efficient duties. SW elements are for seawater desalination and have the highest rejection, at 99.85%.

What does FR mean in SRP BW 8040 FR?

The FR element has a surface treatment that improves hydrophilicity, electric charge and roughness. That reduces the build-up and adsorption of pollutants and microbes on the membrane surface.

What are the operating limits of SRP RO elements?

The maximum operating temperature is 45 °C and the maximum pressure is 41 bar (600 psig). Continuous operation is rated for pH 2–11, and short-term cleaning for pH 1–13. The maximum feed SDI is 5.

Can SRP RO elements tolerate chlorine?

No. Free chlorine must stay below 0.1 ppm. The datasheet recommends removing residual free chlorine by pre-treatment, because oxidation damage can cause early failure.

How much permeate does an 8040 element give?

Under the test conditions in the datasheet, BW, BW FR and ULP 8040 elements give 10,000 gpd (37.9 m³/d), and the SW 8040 gives 7,500 gpd (28.4 m³/d). Permeate flow of individual elements may vary by ±15%.

Do you also design the RO system?

Yes. SRP Membranes makes the elements and SR Paryavaran designs and builds the plant. Send us your feed water data and we will size it.

Talk to our engineers

Tell us about your water.

Share your application and daily flow. We reply with a suitable membrane or a complete treatment system.

  • +91 90565 26208Call or WhatsApp
  • crm@srpepl.comQuotes and datasheets
  • 70, Industrial Area, Phase - I, Panchkula, Haryana, India - 134113Head office
  • Jebel Ali Free Zone, Dubai, U.A.E.International office