Membrane manufacturing division of SR Paryavaran +91 90565 26208crm@srpepl.com

Compare membranes

SRP MBR and UF lines, side by side.

Figures come from the SRP datasheets. Open a product page for full specifications.

MBR and UF comparison
Specification AEROFLO REINFLO HI-FLO ULTRAFLO 3000 ULTRAFLO 4000
Use Submerged MBR Submerged MBR Submerged MBR Pressurised UF Pressurised UF
Membrane material PVDF, corrugated Reinforced PVDF PTFE PVDF Reinforced PVDF
Configuration Flat sheet Capillary Flat sheet Capillary Capillary
Nominal pore size 0.1 µm* 0.03 µm 0.02 µm 0.03 µm 0.03 µm
pH, operation 6–9 1–12 2–12 2–10 2–10
Temperature 5–35 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C
Filtration mode Negative suction Gravity or suction Gravity or suction Dead-end or cross flow Dead-end or cross flow
Typical flux Not stated 10–20 L/m²h (ETP), 20–30 (STP) 15–30 L/m²h 40–100 L/m²h 70–120 L/m²h
Area per unit 5–15 m² per module 40–1,750 m² per cassette 10–480 m² per cassette 40–110 m² per module 25–75 m² per module
Maximum TMP 35 kPa 10–50 kPa 2–10 kPa 0.2 MPa 0.2 MPa
Chlorine for cleaning NaOCl / citric acid NaOCl up to 5,000 mg/L 5,000 ppm 1,000–3,000 ppm 1,000–3,000 ppm

*AEROFLO filtration degree can be changed on client request. REINFLO flux is given for ETP and STP duties. Final selection depends on your feed water. Use the membrane finder or talk to an engineer.

Talk to our engineers

Tell us about your water.

Share your application and daily flow. We reply with a suitable membrane or a complete treatment system.

  • +91 90565 26208Call or WhatsApp
  • crm@srpepl.comQuotes and datasheets
  • 70, Industrial Area, Phase - I, Panchkula, Haryana, India - 134113Head office
  • Jebel Ali Free Zone, Dubai, U.A.E.International office